Q开关Nd∶YAG激光联合微针导入40%乳酸对黄褐斑患者MASI评分及色素斑的影响
DOI:
CSTR:
作者:
作者单位:

重庆市沙坪坝区陈家桥医院皮肤与整形美容科,重庆

作者简介:

通讯作者:

中图分类号:

基金项目:

2025 年度重庆市沙坪坝区技术创新项目(项目编号:2025209)


Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 临床对黄褐斑疾病治疗中,探讨联合应用Q 开关 Nd:YAG 激光 PTP 模式与合微针导入 40% 乳酸的实际意义。方法 本次选择患者均为女性黄褐斑患者(Fitzpatrick Ⅲ?Ⅴ 型),患者数量一共为40例,这些患者年龄从18岁到55岁,选取于2025年12月—2026年02月,分组依据简单随机数字表法,分别为20例对照组(予以单纯 Q 开关 Nd:YAG 激光 PTP 模式治疗)和20例实验组(应用Q 开关 Nd:YAG 激光 PTP 模式联合微针导入 40% 乳酸治疗),各个治疗方法均为2周一次,一共治疗8次,组间在治疗前和治疗后对完成各项指标对比,指标包括:治疗前后MASI 评分、 PGA 医生总体评估结果。结果 40例患者中脱落一共2例,包括对照组1例和实验组1例,最后确定病例38例。治疗后两组 MASI 评分均较基线显著下降(P<0.001);实验组 MASI 下降率(54.23±8.61)% 高于对照组(33.17±7.26)%,差异具有统计学意义(t=7.892,P<0.001)。VISIA 检测提示实验组色斑色素负荷下降更显著;皮肤镜下实验组色素颗粒消散、异常毛细血管改善等级优于对照组(Z=?2.733,P=0.006);实验组 PGA 临床有效率 78.95%,高于对照组 42.11%(Z=?2.816,P=0.005)。结论 Q 开关 Nd:YAG 激光 PTP 模式联合微针导入 40% 乳酸可提升患者主观满意度,且不增加严重不良反应风险。

    Abstract:

    Objective: To investigate the clinical significance of combining the Q-switched Nd:YAG laser PTP mode with microneedling using 40% lactic acid in the treatment of melasma. Methods: A total of 40 female patients with melasma (Fitzpatrick type III–V), aged 18–55 years, were enrolled between December 2025 and February 2026. Patients were randomly assigned using a random number table into two groups: 20 patients in the control group (treated with Q-switched Nd:YAG laser PTP mode alone) and 20 patients in the experimental group (treated with Q-switched Nd:YAG laser PTP mode combined with microneedling using 40% lactic acid). Each treatment session lasted 2 weeks, with a total of 8 treatment sessions per patient. Comparative analyses were conducted before and after treatment across all relevant endpoints, including the MASI score and the overall physician evaluation score (PGA). Results: Among the 40 patients, 2 cases were excluded (1 in the control group and 1 in the experimental group), leaving 38 patients for final analysis. After treatment, the MASI scores in both groups significantly decreased compared to baseline values (P<0.001); however, the rate of MASI reduction in the experimental group (54.23±8.61)% was significantly higher than that in the control group (33.17±7.26)%, with a statistically significant difference (t=7.892, P<0.001). VISIA examination revealed that the experimental group exhibited a more pronounced reduction in pigment load; under dermoscopy, the experimental group demonstrated greater dispersion of pigment granules and superior improvement in abnormal capillaries compared to the control group (Z=2.733, P=0.006); the clinical efficacy rate of PGA in the experimental group was 78.95%, significantly higher than that in the control group (42.11%) (Z=2.816, P=0.005). In conclusion, the combination of Q-switched Nd:YAG laser PTP mode and microneedling with 40% lactic acid can enhance patients" subjective satisfaction without increasing the risk of serious adverse reactions.

    参考文献
    相似文献
    引证文献
引用本文
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-10-19
  • 最后修改日期:2026-10-27
  • 录用日期:2026-10-27
  • 在线发布日期:
  • 出版日期:
文章二维码