水雾钕激光对上颌前牙美学区冠延长患者牙周指标的影响
CSTR:
作者:
作者单位:

作者简介:

王谦(1995.4-),男,黑龙江穆棱人,硕士,医师,主要从事牙周病学相关工作

通讯作者:

中图分类号:

R783

基金项目:


Effect of Water Mist Neodymium Laser on Periodontal Indicators in Patients Undergoing Crown Lengthening in the Aesthetic Zone of Maxillary Anterior Teeth
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 探讨水雾钕激光对上颌前牙美学区冠延长患者牙周指标的影响。方法 选取2023年10月-2025年8月在扬州市口腔医院接受上颌前牙美学区冠延长治疗的70例患者作为研究对象,采用随机数字表法将其分为对照组和观察组,各35例。对照组采用传统冠延长术,观察组采用水雾钕激光行冠延长术,比较两组手术相关指标、牙周指标、美学效果、并发症发生率、修复体固位效果。结果 观察组手术时间短于对照组,术中出血量少于对照组(P<0.05);观察组术后PD低于对照组,KGW高于对照组(P<0.05);观察组术后PES、WES评分及总评分均高于对照组(P<0.05);观察组并发症发生率(2.86%)低于对照组(17.14%)(P<0.05);观察组固位优良率高于对照组,但差异无统计学意义(P>0.05)。结论 水雾钕激光应用于上颌前牙美学区冠延长术,可缩短手术时间、减少术中出血量、促进术后牙周组织恢复、提升美学修复效果,并降低并发症发生率,同时不影响修复体的固位效果。

    Abstract:

    Objective To explore the effect of water mist neodymium laser on periodontal indicators in patients undergoing crown lengthening in the aesthetic zone of maxillary anterior teeth. Methods A total of 70 patients who received crown lengthening in the aesthetic zone of maxillary anterior teeth at Yangzhou Stomatological Hospital from October 2023 to August 2025 were selected as the research subjects. According to the random number table method, they were divided into the control group and the observation group, with 35 patients in each group. The control group was treated with traditional crown lengthening, and the observation group was treated with water mist neodymium laser for crown lengthening. The operation-related indicators, periodontal indicators, aesthetic effect, complication rate and restoration retention effect were compared between the two groups. Results The operation time of the observation group was shorter than that of the control group, and the intraoperative blood loss was less than that of the control group (P<0.05). After operation, the PD of the observation group was lower than that of the control group, while the KGW was higher than those of the control group (P<0.05). After operation, the scores of PES, WES and total score in the observation group were higher than those in the control group (P<0.05). The incidence of complications in the observation group (2.86%) was lower than that in the control group (17.14%) (P<0.05). The excellent and good rate of retention in the observation group was higher than that in the control group, but the difference was not statistically signiffcant (P>0.05). Conclusion The application of water mist neodymium laser in crown lengthening in the aesthetic zone of maxillary anterior teeth can shorten the operation time, reduce intraoperative blood loss, promote the recovery of postoperative periodontal tissues, improve the aesthetic restoration effect, and reduce the incidence of complications, without affecting the retention effect of the restoration.

    参考文献
    相似文献
    引证文献
引用本文

王 谦.水雾钕激光对上颌前牙美学区冠延长患者牙周指标的影响[J].医学美学美容,2026,35(4):17-20.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-03-23
  • 出版日期:
文章二维码