可视化超声技术在自体脂肪移植中的应用
CSTR:
作者:
作者单位:

作者简介:

汪峰(1987.5-),男,安徽黄山人,硕士研究生,主治医师,主要从事自体脂肪移植与吸脂塑形相关工作

通讯作者:

中图分类号:

R622

基金项目:


Application of Visualized Ultrasound Technology in Autologous Fat Transplantation
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 探讨可视化超声技术在自体脂肪移植中的应用效果。方法 选取2023年8月-2025年10月于杭州星光丽格医疗科技有限公司美容外科行自体脂肪移植88例的患者作为研究对象,采用随机数字表法将其分为对照组和观察组,各44例。对照组采用常规自体脂肪移植操作,观察组在对照组基础上联合可视化超声技术,比较两组术后美观度、脂肪成活率、并发症发生率及满意度。结果 观察组术后形态对称性、轮廓平滑度、整体美观度及总评分均高于对照组(P<0.05);观察组脂肪成活率为79.55%,高于对照组的56.82%(P<0.05);观察组并发症发生率(6.82%)低于对照组(22.73%)(P<0.05);观察组满意度(95.45%)高于对照组(79.55%)(P<0.05)。结论 可视化超声技术在自体脂肪移植中的应用,提升了手术操作的精准性与移植脂肪的成活率,有效改善术后美观度,同时降低了并发症发生风险。

    Abstract:

    Objective To explore the application effect of visualized ultrasound technology in autologous fat transplantation. Methods A total of 88 patients who underwent autologous fat transplantation in the Department of Cosmetic Surgery, Hangzhou Starlight BeauCare Clinic Medical Technology Co., Ltd. from August 2023 to October 2025 were selected as the research subjects, and they were divided into the control group and the observation group by the random number table method, with 44 patients in each group. The control group received conventional autologous fat transplantation, and the observation group was combined with visualized ultrasound technology on the basis of the control group. The postoperative aesthetics, fat survival rate, complication rate and patient satisfaction were compared between the two groups. Results The postoperative morphological symmetry, contour smoothness, overall aesthetics and total score of the observation group were higher than those of the control group (P<0.05). The fat survival rate of the observation group was 79.55%, which was higher than 56.82% of the control group (P<0.05). The incidence of complications in the observation group (6.82%) was lower than that in the control group (22.73%) (P<0.05). The satisfaction rate of the observation group (95.45%) was higher than that of the control group (79.55%) (P<0.05). Conclusion The application of visualized ultrasound technology in autologous fat transplantation improves the accuracy of surgical operation and the survival rate of transplanted fat, effectively enhances postoperative aesthetics, and reduces the risk of complications.

    参考文献
    相似文献
    引证文献
引用本文

汪 峰,肖剑光,魏有祝.可视化超声技术在自体脂肪移植中的应用[J].医学美学美容,2026,35(3):126-129.

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-03-11
  • 出版日期:
文章二维码