    摘要:

    聚醚醚酮(PEEK)作为一种高分子材料,是目前最具前景的临床以及口腔医用材料,其高质量 的机械性能,被认为是钛和锆等金属的替代品。因具有良好的物理性能、稳定的化学性能和优异的生物相 容性,使之成为一种新型口腔修复材料。随着研究的深入发展,PEEK及其复合物也引起了口腔医学领域 的关注,也已被广泛用于可摘局部义齿卡环和支架材料、固定义齿修复体、赝覆体和种植体基台,并有望 用于微支抗和正畸弓丝。本文对PEEK材料在口腔医学领域的应用作简要综述,并对PEEK在口腔医学领域 的应用前景及发展方向进行展望,以期为聚醚醚酮在口腔修复领域中的广泛使用奠定坚实基础。

    Abstract:

    Poly-ether-ether-ketone (PEEK) as a polymer material, is currently the most promising clinical and oral medical materials, its high quality mechanical properties is considered to be a substitute for titanium and zirconium and other metals. Because of its good physical properties, stable chemical properties and excellent biocompatibility, it has become a new type of oral repair material. With the in-depth development of research, PEEK and its compounds have also attracted attention in the field of stomatology, and have been widely used in removable local denture clings and scaffold materials, fixed denture prostheses, prostheses and implant abutments, and are expected to be used in micro-anchorage and orthodontic arch wires. In this paper, the application of PEEK materials in the field of stomatology is briefly reviewed, and the application prospect and development direction of PEEK in the field of stomatology are prospected, in order to lay a solid foundation for the wide use of PEEK in the field of oral prosthesis.

    参考文献
    [1] 秦胜男,贾慧,李英.聚醚醚酮在口腔临床中的应用现状 [J].国际口腔医学杂志,2018,45(6):652-656.
    [2] Kurtz SM,Devine JN.PEEK biomaterials in trauma, orthopedic,and spinal implants[J].Biomateria ls.2007,28(32):4845-4869.
    [3] Bathala L,Majeti V,Rachuri N,et al.The Role of Polyether Ether Ketone (Peek) in Dentistry - A Review[J].J Med Life,2019,12(1):5-9.
    [4] 周莉.不同表面处理方法对聚醚醚酮生物复合材料粘结 强度的影响[D].长春:吉林大学,2014.
    [5] Zoidis P,Papathanasiou I,Polyzois G.The Use of a Modified Poly-Ether-Ether-Ketone (PEEK) as an Alternative Framework Material for Removable Dental Prostheses.A Clinical Report[J].J Prosthodont,2016,25(7):580-584.
    [6] 何光霁,张文云.聚醚醚酮在口腔修复学中的应用[J].口 腔医学,2017,37(10):957-960.
    [7] Tannous F,Steiner M,Shahin R,et al.Retentive forces and fatigue resistance of thermoplastic resin clasps[J].Dent Mater,2012,28(3):273-278.
    [8] Arnold C,Hey J,Schweyen R,et al.Accuracy of CADCAM- fabricated removable partial dentures[J].J Prosthet Dent,2018,119(4):586-592.
    [9] Papathanasiou I,Kamposiora P,Papavasiliou G,et al.The use of PEEK in digital prosthodontics: A narrative review[J]. BMC Oral Health,2020,20(1):217.
    [10] Behr M,Rosentritt M,Lang R,et al.Glass fiber-reinforced abutments for dental implants. A pilot study[J].Clin Oral Implants Res,2001,12(2):174-178.
    [11] Stawarczyk B,Eichberger M,Uhrenbacher J,et al.Threeunit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types[J].Dent Mater J,2015,34(1):7-12.
    [12] Stawarczyk B,Beuer F,Wimmer T,et al.Polyetheretherketone- a suitable material for fixed dental prostheses?[J].J Biomed Mater Res B Appl Biomater,2013,101(7):1209-1216.
    [13] Muhsin SA,Hatton PV,Johnson A,et al.Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material[J].Saudi Dent J,2019,31(3):382-391.
    [14] Heimer S,Schmidlin PR,Roos M,et al.Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols[J].J Prosthet Dent,2017,117(3):419-425.
    [15] Heimer S,Schmidlin PR,Stawarczyk B.Discoloration of PMMA,composite,and PEEK[J].Clin Oral Investig,2017,21(4):1191-1200.
    [16] 鲁晨,陶璐,项闫颜,等.聚醚醚酮改性及在口腔种植领域 的应用研究[J].实用口腔医学杂志,2020,36(5):819-824.
    [17] Li H,Fu J,Erlong N,et al.Characterization of periprosthetic environment microbiome in patients after total joint arthroplasty and its potential correlation with inflammation[J].BMC Infect Dis,2023,23(1):423.
    [18] Wu T,Fan H,Ma R,et al.Effect of lubricant on the reliability of dental implant abutment screw joint:An in vitro laboratory and three-dimension finite element analysis[J].Mater Sci Eng C Mater Biol Appl,2017,75:297- 304.
    [19] Schwitalla AD,Abou-Emara M,Zimmermann T,et al.The applicability of PEEK-based abutment screws[J].J Mech Behav Biomed Mater,2016,63:244-251.
    [20] Wang B,Huang M,Dang P,et al.PEEK in Fixed Dental Prostheses:Application and Adhesion Improvement[J]. Polymers (Basel),2022,14(12):2323.
    [21] Raj DA,Chander NG,Reddy JR,et al.Clinical acceptability of PEEK fixed dental prosthesis in partially edentulous patient - A one year single arm pilot study[J].J Oral Biol Craniofac Res,2020,10(4):523-528.
    [22] Khurshid Z,Nedumgottil BM,Ali RMM,et al.Insufficient Evidence to Ascertain the Long-Term Survival of PEEK Dental Prostheses:A Systematic Review of Clinical Studies[J].Polymers (Basel),2022,14(12):2441.
    [23] Neumann EA,Villar CC,Fran?a FM.Fracture resistance of abutment screws made of titanium, polyetheretherketone,and carbon fiber-reinforced polyetheretherketone[J].Braz Oral Res, 2014,28:S1806-83242014000100239.
    [24] Koutouzis T,Richardson J,Lundgren T.Comparative soft and hard tissue responses to titanium and polymer healing abutments[J].J Oral Implantol,2011,37:174-182.
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

麦麦提艾力?麦麦提敏,郭 莎,等.聚醚醚酮(PEEK)在口腔修复中的应用和研究进展[J].医学美学美容,2023,32(22):187-190.

复制
分享
文章指标
  • 点击次数:553
  • 下载次数: 0
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2023-12-18